2016 improved version of the electronic hardware sequencer designed in collaboration with Marc Sirguy from Eowave

Pad 1. NOTES (Steps): Tap on or off to arm notes. 1/8 notes are on the outside circle, 1/16 notes inner. Press and hold a step, turn the encoder to change the pitch.
Pad 2VEL (Velocity): Sets velocity value. Press and hold a step, turn the encoder to change the amount.
Pad 3. LENGTH: Sets length of individual step—think of it as sustain. Press and hold a step, turn the encoder to increase the length to up to 16th bars. 
Pad 4. RETRIG (Retrigger): Sets the amount of times the step will be repeated. Press and hold a step, turn the encoder to set the number of repeats. 
Pad 5. TOUCH: Pressure sensitive “Key” mode—at this point a stepping Theremin.
Pad 6. KEY: Allows individual control of notes which sustain while pressed; also sets note range and reset point: select one of the 16 pads for the start note, and another for the end.
Pad 7. GLOBAL: The first four default parameters set the direction of sequence: 
> Forward direction
< Backward direction
<> Pendulum
RND (Random) Selects a designless firing of notes. To access and change values for sub functions TUNE, SCALE, LEGATO, GLIDE, CHAN, SYNC, press and hold desired step, and turn encoder. 
TUNE: Tunes the CV output; hold the pad and turn the encoder to adjust the overall tuning.
SCALE: Sets one of sixteen scales; default is chromatic.
LEGATO: Sets the legato; only legato notes will glide.
GLIDE: On/off & speed. Hold the pad and turn the encoder to adjust the glide time.
CHAN (Channel): Sets the base MIDI channel—you only can change the base midi channel; other tracks add that base channel # to their track number like so: if Base MIDI CH is 1, TK 1 -> CH1, TK2-> CH2... TK8-> CH8. If base MIDI CH is 4, TK 1 -> CH4, TK2-> CH5... TK8-> CH12. If base MIDI CH is 6, TK 1 -> CH6, TK2-> CH7, TK8-> CH14 and so on. 
SYNC: Surrenders sequencer to external clock. 
Pad 8. SHUFFLE: Sets swing before or after note.
Pad 9. LOAD: Loads preset into RAM by turning encoder, or selecting preset.
Pad 10. SAVE: Saves presets to 128 locations: 8 banks of 16 presets. press the encoder to validate your choice. 
Pad 11. BANK: Selects 1 of 8.
Pad 12. TRK (TRACK) PLAY: Selects which tracks are played together or not. Also sets the editing/performance mode for tracks: enable, mute, or edit.
Pad 13. RND TRK (Random Track): Randomizes entire sequence not just direction. Continued presses produce ever more random results.
Pad 14. CLEAR: Clears the active preset's tracks.
Pad 15. TRACK (Groups of 16-128 steps): Selects track to be edited on outer circle—mute track on inner circle. 
Pad 16. TRANSP (Transpose): Each pressure pad changes key, or turning encoder in TRANSPOSE mode changes key.
SHIFT: Press and hold for selecting feature set mode; pressed together with PLAY will activate record.  

Highlights, Clarifications, and Recaps
Breakout box (BBox) allows for 4x multichannel/mult-CV use.
Up to 2 breakout boxes can be connected to generate up to 8 CVs and 8 gate outputs.
Per note/track pitch, velocity, and length, with 256 track memory locations. 
 
Patch It
Eight patch points: CV INCLOCK INRESET INCLOCK (out), RESET (out), VEL (out),  GATE (out), CV (out).
 
Patch Points Detail
CV IN – Control voltage input. 
CLOCK IN – Clock source can be a square wave or gate signal (positive logic).
RESET IN – Positive voltage resets the Sequencer to the first step.
CLOCK (out) – Outputs a pulse per step. The default step setting is 1/16 (1/16th note). in note mode press SHIFT and PLAY together, and turn the encoder to divide the master tempo.
RESET (out) – Positive reset voltage output.
VEL (out) – Velocity (note/step level) output.
GATE (out) – 0/+5v trigger  output.
CV (out) – Control Voltage output.
 
Additional Connections
USB in/out - Update software via USB HIDBootloader/Import and export sequence data via Max7.
 
Vitals
Size - 26hp

Distribué par mesi

»

Autres catégories dans Synthétiseurs modulaires

Autres dénominations : charcotcircles